Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Journal of Parenteral and Enteral Nutrition
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Deitel, M.
Right arrow Articles by Cantwell, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Deitel, M.
Right arrow Articles by Cantwell, E.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

An Outbreak of Staphylococcus Epidermidis Septicemia

Mervyn Deitel, M.D., F.R.C.S. C, F.A.C.S.

Department of Surgery, University of Toronto; St. Joseph's Health Centre, Toronto, Department of Laboratories, Division of Microbiology, St. Joseph's Health Centre, Toronto, Ontario, Canada

Sigmund Krajden, M.D., F.R.C.P. C

Department of Surgery, University of Toronto; St. Joseph's Health Centre, Toronto, Department of Laboratories, Division of Microbiology, St. Joseph's Health Centre, Toronto, Ontario, Canada

Colin F. Saldanha, M.D.

Department of Surgery, University of Toronto; St. Joseph's Health Centre, Toronto, Department of Laboratories, Division of Microbiology, St. Joseph's Health Centre, Toronto, Ontario, Canada

Wayne D. Gregory, M.D.

Department of Surgery, University of Toronto; St. Joseph's Health Centre, Toronto, Department of Laboratories, Division of Microbiology, St. Joseph's Health Centre, Toronto, Ontario, Canada

Milan Fuksa, D.SC.

Department of Surgery, University of Toronto; St. Joseph's Health Centre, Toronto, Department of Laboratories, Division of Microbiology, St. Joseph's Health Centre, Toronto, Ontario, Canada

Ellen Cantwell, B.Sc.N.

Department of Surgery, University of Toronto; St. Joseph's Health Centre, Toronto, Department of Laboratories, Division of Microbiology, St. Joseph's Health Centre, Toronto, Ontario, Canada

During 45 wk from August 1980 to June 1981, the catheter sepsis rate increased from a prior 2 to 34% (23 of 68 patients on intravenous hyperalimentation). The causative organism was Staphylococcus epidermidis, grown on blood cultures in 21 of the 23 patients and on the catheter-tips of all 23. Routine cultures of the catheter-tips of the 45 patients who received intravenous hyperalimentation during this period with no evidence of catheter sepsis grew S. epidermidis on three catheter-tips (6.7%), possibly contamination during catheter removal. Sepsis resolved within 24 hr after catheter removal, with no antibiotics given for the sepsis. The organism had identical antibiograms on the blood and catheter-tip cultures in each patient, but antibiograms varied between patients. In these complex patients undergoing multiple medical events, the intravenous hyperalimentation nurse recorded that iv tubing in septic patients had leaked solution at the attachment to the catheter hub, and a review of nursing notes on charts of patients who had been on intravenous hyperalimentation revealed that a leak had been noted in the patients who subsequently had catheter sepses. The leak was due to a manufacturing defect resulting in a decrease in diameter of the plastic connection of the iv tubing, which produced a loose attachment to the hub. The problem was remedied by switching to a Luer-lok attachment. However, in July 1982, two patients had separation of the Luer due to a manufacturing defect in the threads, followed by a catheter sepsis. Sepsis from the local contamination was not manifest until 5.4 ± 2.7 days later. Quality control by manufacturers is emphasized. (Journal of Parenteral and Enteral Nutrition 7: 569-572, 1983)

Journal of Parenteral and Enteral Nutrition, Vol. 7, No. 6, 569-572 (1983)
DOI: 10.1177/0148607183007006569


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
Nutr Clin PractHome page
J. A. Kruse and N. J. Shah
Detection and Prevention of Central Venous Catheter-Related Infections
Nutr Clin Pract, August 1, 1993; 8(4): 163 - 170.
[Abstract] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
Y. Inoue, R. Nezu, H. Matsuda, M. Fuj, S. Nakai, M. Wasa, Y. Takagi, and A. Okada
Prevention of Catheter-Related Sepsis During Parenteral Nutrition: Effect of a NeW Connection Device
JPEN J Parenter Enteral Nutr, November 1, 1992; 16(6): 581 - 585.
[Abstract] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
Y. Inoue, R. Nezu, H. Matsuda, M. Fuj, S. Nakai, M. Wasa, Y. Takagi, and A. Okada
Experimental Study of Hub Contamination: Effect of a New Connection Device: The I System
JPEN J Parenter Enteral Nutr, March 1, 1992; 16(2): 178 - 180.
[Abstract] [PDF]


Home page
Nutr Clin PractHome page
D. K. Henderson
Of Snakes and Bugs: Nosocomial Infection Associated with Nutritional Support
Nutr Clin Pract, April 1, 1991; 6(2): 39 - 41.
[PDF]


Home page
Arch Intern MedHome page
E. Cercenado, J. Ena, M. Rodriguez-Creixems, I. Romero, and E. Bouza
A Conservative Procedure for the Diagnosis of Catheter-Related Infections
Arch Intern Med, July 1, 1990; 150(7): 1417 - 1420.
[Abstract] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
C. Powell, P. J. Fabri, and K. A. Kudsk
Risk of Infection Accompanying the Use of Single-Lumen vs Double-Lumen Subclavian Catheters: A Prospective Randomized Study
JPEN J Parenter Enteral Nutr, March 1, 1988; 12(2): 127 - 129.
[Abstract] [PDF]


Home page
JAMAHome page
D. G. Maki, J. T. Botticelli, M. L. LeRoy, and T. S. Thielke
Prospective Study of Replacing Administration Sets for Intravenous Therapy at 48- vs 72-Hour Intervals: 72 Hours Is Safe and Cost-effective
JAMA, October 2, 1987; 258(13): 1777 - 1781.
[Abstract] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
A. T. Stotter, H. Ward, A. H. Waterfield, J. Hilton, and A. J.W. Sim
Junctional Care: The Key to Prevention of Catheter Sepsis in Intravenous Feeding
JPEN J Parenter Enteral Nutr, March 1, 1987; 11(2): 159 - 162.
[Abstract] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
L. M. Murphy and T. O. Lipman
Central Venous Catheter Care in Parenteral Nutrition: A Review
JPEN J Parenter Enteral Nutr, March 1, 1987; 11(2): 190 - 201.
[Abstract] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
P. A. Gibilisco, G. A. Lopez, M. D. Appleman, W. J. Millburg, D. L. Kushell, L. Elowitz, P. A. Johnson, and D. Zenowich
In Vitro Contamination of "Piggyback/Heparin Lock" Assemblies: Prevention of Contamination with a Closed, Positive Locking Device (Click-Lock)
JPEN J Parenter Enteral Nutr, July 1, 1986; 10(4): 431 - 434.
[Abstract] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
A. Sitges-Serra, J. Linares, J.L. Perez, E. Jaurrieta, and L. Lorente
A Randomized Trial on the Effect of Tubing Changes on Hub Contamination and Catheter Sepsis during Parenteral Nutrition
JPEN J Parenter Enteral Nutr, May 1, 1985; 9(3): 322 - 325.
[Abstract] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
L. B. Pemberton, B. Lyman, J. Mandal, and J. Covinsky
Outbreak of Staphylococcus epidermidis Nosocomial Infections in Patients Receiving Total Parenteral Nutrition
JPEN J Parenter Enteral Nutr, May 1, 1984; 8(3): 325 - 326.
[PDF]