Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Journal of Parenteral and Enteral Nutrition
This Article
Right arrow Free Full Text Free
Right arrow Free Full Text (Free PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by DeChicco, R.
Right arrow Articles by Lopez, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by DeChicco, R.
Right arrow Articles by Lopez, R.
Right arrowPubmed/NCBI databases
Medline Plus Health Information
*Deep Vein Thrombosis
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Premier Research

Tip Position of Long-Term Central Venous Access Devices Used for Parenteral Nutrition

Robert DeChicco, MS, RD, CNSD*, Douglas L. Seidner, MD, FACG, CNSP*,{dagger}, Carlos Brun, MD, CNSP*, Ezra Steiger, MD, FACS, CNSP*,{ddagger}, Judy Stafford, RN* and Rocio Lopez, MS, MPH§

From the * Nutrition Support Team and Departments of {dagger} Gastroenterology and Hepatology,{ddagger} General Surgery, and§ Quantitative Health Sciences, Cleveland Clinic, Cleveland, Ohio

Correspondence: Robert DeChicco, MS, RD, CNSD, Nutrition Support Team TT22, Cleveland Clinic, Cleveland, OH 44145. Electronic mail may be sent to dechicb{at}ccf.org.

Background: Venous thrombosis is a potential postplacement complication of a central venous access device (VAD). Improper catheter tip position is a predisposing factor, especially when the device is used to administer parenteral nutrition (PN). American Society for Parenteral and Enteral Nutrition (A.S.P.E.N.) guidelines recommend that a central VAD used for PN be placed with its tip in the superior vena cava (SVC) adjacent to the right atrium (RA). The purpose of this study is to determine the prevalence of improper central VAD tip position and factors associated with malpositioning. Methods: All adult patients with a longterm VAD (ie, tunneled central venous catheter, peripherally inserted central catheter [PICC], or implanted port) placed before the current admission who were scheduled to receive PN also received chest x-rays to evaluate position of the catheter tip. Position was determined by a staff radiologist. A catheter with its tip ranging from the middle third of the SVC to the RA was considered acceptable; a catheter with its tip in any other position was considered malpositioned. Subjects with multiple VADs or multiple evaluations for the same catheter had the first placement and last evaluation considered. A logistic regression analysis was used to study the univariable and multivariable associations of these factors with tip malposition. Results: Data were collected for catheters in 124 patients, including 74 tunneled catheters (71 Hickman, 2 Broviac, 1 Groshong), 38 PICCs, and implanted ports. Most of the catheters were placed for (81.9%) or chemotherapy (14.5%). Median catheter duration was 1.6 months at time of evaluation. Of 138 catheters ied, 15.9% (95% confidence interval, 10.2–23.1) were sitioned at time of evaluation. According to univariable ysis, factors associated with malpositioned catheters included shorter catheter duration (p = .001), greater ber of lumens (p = .029), venous entry site on the arm (p .001) and catheters placed at institutions other than Cleveland Clinic (p = .007). Additionally, PICCs were likely to be malpositioned at time of evaluation compared with other long-term VADs combined (34.2% vs 9.0%; p .001). Conclusions: A high percentage of long-term VADs improperly positioned for PN in the present study. were more likely to be malpositioned at time of evaluation compared with tunneled catheters and implanted These findings suggest the tip position of long-term should be confirmed before infusing PN.

Journal of Parenteral and Enteral Nutrition, Vol. 31, No. 5, 382-387 (2007)
DOI: 10.1177/0148607107031005382


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?