Central Catheter-Related Infections: Comparison of Pulmonary Artery Catheters and Triple Lumen Catheters for the Delivery of Hyperalimentation in a Critical Care Setting
Harold W. Horowitz, M.D.
Departments of Medicine, Surgery, and Nursing, New York Medical College, Valhalla, New York
Brad M. Dworkin, M.D.
Departments of Medicine, Surgery, and Nursing, New York Medical College, Valhalla, New York
John A. Savino, M.D.
Departments of Medicine, Surgery, and Nursing, New York Medical College, Valhalla, New York
Daniel W. Byrne, B.A.
Departments of Medicine, Surgery, and Nursing, New York Medical College, Valhalla, New York
Nanette A. Pecora, R.N.
Departments of Medicine, Surgery, and Nursing, New York Medical College, Valhalla, New York
We prospectively studied the risk of catheter-related sepsis (CRS) in 75 critically ill patients who received total parenteral nutrition (TPN) through 158 pulmonary artery catheters (PACs) and 214 triple-lumen catheters (TLCs). We relied on semiquantitative cultures of the catheter tips, peripheral blood cultures in febrile patients and clinical response to catheter removal to diagnose catheter-related sepsis. The infection rate was 2.5% (4/158) of PACs and 6.5% (14/214) of TLCs (p=0.124). Colonization rates were 29.1% for PACs and 32% for TLCs. PACs were left in place a significantly shorter length of time than TLCs, 3.1 vs 5.1 days (p<0.005). Guidewire exchanges and subclavian vein insertions were associated with a decreased rate of CRS when compared to new insertions and internal jugular vein insertions, respectively.
We conclude that pulmonary artery catheters can be used safely for the delivery of hyperalimentation in critically ill patients with no increased risk for catheter-related sepsis compared to triple-lumen catheters. The use of the PAC in this manner allows for the use of a single central venous catheter for the delivery of hyperalimentation and hemodynamic monitoring. (Journal of Parenteral and Enteral Nutrition 14:588-592, 1990)
Journal of Parenteral and Enteral Nutrition, Vol. 14, No. 6,
588-592 (1990)
DOI: 10.1177/0148607190014006588

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
D. G. Maki, D. M. Kluger, and C. J. Crnich
The Risk of Bloodstream Infection in Adults With Different Intravascular Devices: A Systematic Review of 200 Published Prospective Studies
Mayo Clin. Proc.,
September 1, 2006;
81(9):
1159 - 1171.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Zurcher, M. R. Tramer, and B. Walder
Colonization and Bloodstream Infection with Single- Versus Multi-Lumen Central Venous Catheters: A Quantitative Systematic Review
Anesth. Analg.,
July 1, 2004;
99(1):
177 - 182.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. P. Borzotta and K. Beardsley
Candida Infections in Critically Ill Trauma Patients: A Retrospective Case-Control Study
Arch Surg,
June 1, 1999;
134(6):
657 - 665.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
N. P. Ritchey, L. P. Caccamo, K. J. Carter, F. Castro, B. A. Erickson, W. Johnson, E. Kessler, and C. A. Ruiz
Optimal Interval for Triple-lumen Catheter Changes: A Decision Analysis
Med Decis Making,
June 1, 1995;
15(2):
138 - 142.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
L. Kemp, J. Burge, P. Choban, J. Harden, J. Mirtallo, and L. Flancbaum
The Effect of Catheter Type and Site on Infection Rates in Total Parenteral Nutrition Patients
JPEN J Parenter Enteral Nutr,
January 1, 1994;
18(1):
71 - 74.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Evans and M. A. Ryder
Invited Review: Vascular Access Devices: Perspectives on Designs, Complications, and Management
Nutr Clin Pract,
August 1, 1993;
8(4):
145 - 152.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
J. A. Kruse and N. J. Shah
Detection and Prevention of Central Venous Catheter-Related Infections
Nutr Clin Pract,
August 1, 1993;
8(4):
163 - 170.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
N. Clark-Christoff, V.A. Watters, W. Sparks, P. Snyder, and J.P. Grant
Response to Dr Wright et al
JPEN J Parenter Enteral Nutr,
May 1, 1993;
17(3):
297 - 298.
[PDF]
|
 |
|

|
 |

|
 |
 
N. Clark-Christoff, V. A. Watters, W. Sparks, P. Snyder, and J. P. Grant
Use of Triple-Lumen Subclavian Catheters for Administration of Total Parenteral Nutrition
JPEN J Parenter Enteral Nutr,
September 1, 1992;
16(5):
403 - 407.
[Abstract]
[PDF]
|
 |
|
|
|