Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Journal of Parenteral and Enteral Nutrition
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Powell, C.
Right arrow Articles by Fabri, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Powell, C.
Right arrow Articles by Fabri, P. J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Clinical Trial

Effect of Frequent Guidewire Changes on Triple-Lumen Catheter Sepsis

Carla Powell, R.N.

Department of Surgery, The Ohio State University College of Medicine, Columbus, Ohio

Kenneth A. Kudsk, M.D.

Department of Surgery, The Ohio State University College of Medicine, Columbus, Ohio

Patricia A. Kulich, R.N.

Department of Surgery, The Ohio State University College of Medicine, Columbus, Ohio

Jon A. Mandelbaum, M.D.

Department of Surgery, The Ohio State University College of Medicine, Columbus, Ohio

Peter J. Fabri, M.D.

Department of Surgery, The Ohio State University College of Medicine, Columbus, Ohio

Frequent guidewire changes of single-lumen (SLC) and triple-lumen (TLC) catheters have been proposed to decrease catheter sepsis. We placed TLC in 126 patients needing total parenteral nutrition (TPN) and multiple venous access, prospectively randomizing them to two groups: group I received a guidewire change every 3 days, and group II received guidewire changes for mechanical or septic complications only. Tips were cultured at each line change and tips and blood for each septic episode. Catheter sepsis was defined by the criteria of the Association for Practitioners in Infection Control (APIC). There were 67 positive cultures in 52 patients, but most produced very few colonies or grew the same organisms in other infection sites. Forty-seven% of all cultures grew Staphylococci, and 23% grew Candida. APIC-defined catheter sepsis was detected in 12.7% of group I and 15.9% of group II. Although we observed no statistically significant difference in the two techniques, if we assume that a 20% difference in the incidence of catheter-induced sepsis would be important to detect, the probability of failing to detect such a difference is 0.24 with an 0.05 level of significance (two-sided). Prophylactic guidewire changes did not alter the incidence of catheter sepsis in patients with TLC who required TPN. The high rate of sepsis and Candida infection may be due to the critical illness of the immunocompromised population studied. (Journal of Parenteral and Enteral Nutrition 12:462-464, 1988)

Journal of Parenteral and Enteral Nutrition, Vol. 12, No. 5, 462-464 (1988)
DOI: 10.1177/0148607188012005462


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
PediatricsHome page
N. P. O'Grady, M. Alexander, E. P. Dellinger, J. L. Gerberding, S. O. Heard, D. G. Maki, H. Masur, R. D. McCormick, L. A. Mermel, M. L. Pearson, et al.
Guidelines for the Prevention of Intravascular Catheter-Related Infections
Pediatrics, November 1, 2002; 110(5): e51 - 51.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
T. Bregenzer, D. Conen, P. Sakmann, and A. F. Widmer
Is Routine Replacement of Peripheral Intravenous Catheters Necessary?
Arch Intern Med, January 26, 1998; 158(2): 151 - 156.
[Abstract] [Full Text] [PDF]


Home page
Nutr Clin PractHome page
J. A. Kruse and N. J. Shah
Detection and Prevention of Central Venous Catheter-Related Infections
Nutr Clin Pract, August 1, 1993; 8(4): 163 - 170.
[Abstract] [PDF]


Home page
JPEN J Parenter Enteral NutrHome page
N. Clark-Christoff, V.A. Watters, W. Sparks, P. Snyder, and J.P. Grant
Response to Dr Wright et al
JPEN J Parenter Enteral Nutr, May 1, 1993; 17(3): 297 - 298.
[PDF]


Home page
NEJMHome page
T. Feldman, P. J. Fabri, J. D. Rizzo, B. L. Strom, J. Berlin, D. K. Cobb, K. P. High, and B. M. Farr
Replacement of Central Vascular Catheters
N. Engl. J. Med., February 11, 1993; 328(6): 445 - 446.
[Full Text]


Home page
JPEN J Parenter Enteral NutrHome page
N. Clark-Christoff, V. A. Watters, W. Sparks, P. Snyder, and J. P. Grant
Use of Triple-Lumen Subclavian Catheters for Administration of Total Parenteral Nutrition
JPEN J Parenter Enteral Nutr, September 1, 1992; 16(5): 403 - 407.
[Abstract] [PDF]


Home page
Nutr Clin PractHome page
S. L. Cahill and P. N. Benotti
Invited Review: Catheter Infection Control in Parenteral Nutrition
Nutr Clin Pract, April 1, 1991; 6(2): 65 - 67.
[Abstract] [PDF]